Instruction Manual
Automatic Digital
Blood Pressure Monitor
Model HEM-703CP
HEM-703CP-xxxx 0692581-7 A
Name and Function of Each Part
Main Unit
Systolic Bood Pressure Display
Diastolic Blood Pressure and Pulse Display
Printing Paper
Air Jack
Paper Cutter
MODE Selector Button
SET Button
SPHYG/CLOCK Button
START Button
PRINT / PAPER FEED Button
Cuff
Tab
Air Plug
Air Tube
2
Preparations for Use
1 How to insert the batteries
1ꢀ Take off the battery cover at the back of
the main unit by sliding it in the direction
indicated by the arrow symbolꢀ
Replacement
• When the “Replace Batteries” symbol
Battery Cover
(
) flashes during measurement,
please replace the batteries with the
new onesꢀ
• When the batteries have run down,
random numbers may be displayedꢀ
Points to be careful about whan using
the batteries
• When replacing the batteries please
replace all four batteries at onceꢀ
• Use the same kind of batteriesꢀ
• Take out weak batteries quickly so as to
avoid causing damage to the machineꢀ
• Remove the batteries when the unit is
not used for extended periodsꢀ
2ꢀ Install 4 “AA” size batteries attached so
that the
+
and
-
polarities on the
batteries correctly match the polarities in
the battery compartmentꢀ
3ꢀ Replace the coverꢀ
3
Preparations for Use
2 How to Set Time and Date
3 Plug in and Turn on
1ꢀ When batteries are installed, the display
shows PM 12:00ꢀ
1ꢀ Insert the air plug into the air jack on the
left side of the main unit correctlyꢀ
2ꢀ When the MODE button
is pressed
down, the “month” sign is displayedꢀ
When the SET button is pressed down,
the figure for the month increasesꢀ Adjust
the “month”ꢀ
2ꢀ When the SPHYG/CLOCK button is
changedtothesphygmomanometermode,
all the LCD symbols are momentarily
displayedꢀ This happens because the unit
is running a check on the display and this
state lasts for approximately one secondꢀ
3ꢀ When the MODE button
is pressed
down after the “month” has been adjusted,
the “day” sign is displayedꢀ Adjust the
“day” in the same way as the “month”ꢀ
Initial Display
3ꢀ Once the LCD symbols vanish, the air
release indication symbol ( ) starts
flashingꢀ Please wait until the ( ) symbol
goes outꢀ
4ꢀ In the same manner select the “hour” and
“minꢀ” with the MODE button
and set
each value with the SET button ꢀ AM and
PM signs are switched in accordance with
the “hour” adjsutmentꢀ
Air release
indication symbol
4ꢀ When the preparations necessary before
measurement have been completed, the
unit emits a series of beeps and finally the
“Ready to Measure” symbol ( ♥ ) will be
displayedꢀ
5ꢀ Press the MODE button for the last time
and return the screen to normal time (hour,
minꢀ) displayꢀ
“Ready to Measure”
Display
4
Preparations for Use
4 How to Set the Printing Paper
Please be sure not to print without inserting
printing paper as it will shorten the life span
of the printer headꢀ
4ꢀ Insert the printing paper in the installation
section, and then attach the cover back to
the main unit in such a way that the edge
of the paper protrudes from the coverꢀ
1ꢀ Slide the plastic printer cover in the
direction indicated by the arrow symbol
and remove it from the main unitꢀ
5ꢀ When the PRINT/PAPER FEED button
is pressed while the results of the
measurement are shown on the digital
display, these results, together with the
date and time of measurement are printed
outꢀ
2ꢀ Peel off the glued edge of the prontlng
paper included with the unit, and cut it off
to about 2 inches with a pair of scissors,
and then shape and cut the edge for easy
insertion to the printer as shown in the
figureꢀ
Reverse
6ꢀ When purchasing printing paper, ask at the
shop where you purchased the main unit
for further supplyꢀ Other brands of paper
may be used providing the dimensions are
smaller than 38mm wide and 20mm in di-
ameterꢀ However the printing quality may
differ a littleꢀ
Inserting Direction
Front
3ꢀ Press the PRINT/PAPER FEED button
while inserting the edge of the printing
paper to the paper feeding slitꢀ When the
edge of the paper protrudes sufficiently,
release the button and stop feedingꢀ
5
Preparations for Use
5 Changing the Printer Ink
Though not originally equipped with an ink
roller, the HEM-703CP digital blood pressure
monitor contains enough printer ink to last
about two years when used once a day at
normal room temperatureꢀ
3ꢀ Insert the supplement ink roller into the
allotted space next to the printerꢀ
Supplement ink roller
When the ink on the print out becomes light
and hard to read, purchase a replacement ink
roller from your retailer and install as fol-lowsꢀ
1ꢀ Remove the printer coverꢀ
4ꢀ Replace the printer coverꢀ
2ꢀ Removethe ink, which came with the
unit when you bought it, from the allotted
spaceꢀ
NOTE: The supplement ink roller should
last about two years, however, if you
need to replace the supplement ink
roller, simply grasp the top of the ink
roller and turn itslightlycounterc1ock-
wise before lifting the roller from the
printerꢀ
6
Preparations for Use
6 Attach the Cuff
This cuff has eliminated the need for
a
3ꢀ Place your arm on a table or a support with
the palm facing upward so that the cuff is
placed at the same level as the heartꢀ
microphone thereby lessening possible
interference from vibrations and noiseꢀ Fitting
also has been made much easier through the
widening of the artery oscillation detection
areaꢀ
1ꢀ Place the cuff on the left arm so that the air
tube lies across the center of the armꢀ
Artery
no space
2ꢀ Wrap the cuff pulling in a diagonal angle
securely so that the cuff tab is positioned
about one inch above the elbow joint of the
inner your left upper armꢀ (Over the brachi-
al artery)ꢀ
There should be no space between the
cuff and your armꢀ
NOTE: If you have any difficulties wrap-ping
cuff by yourself, we recom-mend that
you ask someone to wrap the cuff for
youꢀ
about 1 inch
7
Preparations for Use
7 Apply Pressure to the Cuff
1ꢀ When you press the start button, the pump
operates and pressure is appliedꢀ When
the pressure reaches 170mmHg, the
pump stops automaticallyꢀ
Depress the START
button continuously
untill the cuff is inflated
up to the targeted
pressureꢀ
After the cuff has
been inflated,
release the START
buttonꢀ
Pressure being applied
2ꢀ When the appropriate pressure has been
reached, the air is automatically released
and the value on the display window
starts to decreaseꢀ After a while when the
artery oscillations are detected, the ( ♥ )
symbol starts flashing and the unit emits
a beep-ing sound simultaneouslyꢀ The
value shown on the display will continue
to fallꢀ
Notes:
*
If your systolic blood pressure is higher
than 140mmHg, the pump starts again and
the cuff will be inflated up to 210mmHgꢀ
If your systolic blood pressure is higher
than 180mmHg, sufficient inflation will
not be applied to the cuff by automatic
reinflationꢀ In this case, inflate up to
30mmHg higher than your expected
systolic blood pressure by pressing the
start button continuouslyꢀ While press-ing
the start button, the cuff can be in-flated
continuously, and when the start button
is released, the pump stops and the cuff
is no longer inflatedꢀ When the pressure
reaches 300mmHg, the cuff deflates
rapidlyꢀ
*
*
During measurement, do not shake
the cuff or the air tubeꢀ
Targetted Blood
Pressure Reached
Indicated Value Drops
Measuring
*
When you want to stop measurememt,
press SPHYG/CLOCK buttonꢀ The pres-
sure will stop and the air is deflated rapidlyꢀ
8
Preparations for Use
8 Blood Pressure and Pulse are displayed
1ꢀ When the unit has continued to deflate
to a point when the artery oscillations are
no longer detected, the unit will display
the systolic and diastolic blood pressure
values, along with a long beep, and causes
the deflation indication symbol ( ) to start
flashingꢀ After this, blood pressure and the
pulse readings are displayed alter-natelyꢀ
*
When you wish to stop measuring during
operation, press the SPHYGICLOCK
buttonꢀ The pump will stop and all the cuff
pressure will be released rapidlyꢀ
*
When the PRINT button is pressed while
the results of the measurement are shown
on the digital display, the results will be
printedꢀ
3ꢀ Measurement of the blood pressure is
now completeꢀ The results will remain
displayed even after the cuff is taken
offꢀ If you wish to carry out repeated
measurements, repeat the operation from
Step 6ꢀ
Measurement
Completed
When the deflation symbol begins to flash,
the residual pressure in the cuff is then
rapidly releasedꢀ
*
The arm gradually becomes congested
when measurements are repeatedly
takenꢀ If you wish to take consecutive
measurements, take off the cuff and
wait at least 3 to 5 minutes between
measurementsꢀ
2ꢀ Upon total cuff deflation,
a
series of
beeps are emitted and the ( ♥ ) symbol is
displayedꢀ
Alternate Display
4ꢀ When measurement is completed press
the SPHYG/CLOCK button to return to the
time displayꢀ If you should forget to press
this button, the display will return to time
display mode automatically after about 5
minutesꢀ
Blood Pressure
Reading Display
(for approxꢀ
seconds)
3
Pulse Reading
Display
(for approxꢀ 1ꢀ5
seconds)
*P: Stands for PULSEꢀ
9
When Error Indication Symbols Appear
The following special error symbols will appear in the display if the unit is being used incorrectly:
ERROR SYMBOL
CAUSE
CORRECTION
1ꢀ Cuff underinflated
1) Release air pressure in cuff
2) Wait 10 minutes before taking
another readingꢀ
3) Repeat “Instructions for Use”
steps except inflate cuff 30
mmHg higher than previous
inflation valueꢀ
2ꢀ Movement during
measurement
Residual air pressure
in cuffꢀ
1) Release air pressure in cuff
2) Wait 10 minutes before taking
another readingꢀ
Cuff overinflated (more
than 300 mmHg)ꢀ
No pulse or blood
pressure reading due to:
1) Motion
2) Very weak artery
oscillation
3) Repeat “Instructions for Use”
steps
10
Specifications
Power Source:
Battery (four type “AA” dry cell batteries) 6V 4W
Oscillometric Method
Measurement Method:
Display:
Liquid Crystal Digital Display
Measurement Range:
Pressure: 0 ~ 280mmHg
Pulse: 40 ~ 200/minute
Accuracy:
Pressure: within ± 3 mmHg
Pulse: within ± 5% reading
Pressure Detection:
Capacitive Pressure Sensor
Inflation:
Automatic Pressure Application by a Pump
Automatic pressure release valve
Deflation and Rapid Air Release:
Automatic-shut-off System
When the internal pressure in the unit continues
at less than 20mmHg for about 5 ~ 8 minutes, the
mode changes automatically to clockꢀ
Printer:
Serial static impact printer
Operating/Temperature, Humidity:
StorageiTemperature, Humidity:
Dimensions (Approxꢀ):
+500F to +104°F (+100C to +40 0C) 30-85% RH
-4°F to 140°F (-20°C to + 600C) 10-95% RH
2
1
3
/
/
/
Main Unit:
8
4” (w) X 5 8” (d) x 2 5” (h) (215
x 130x 66 mm)
Cuff: 5 2 “(w) x 18 5”(1) (140x 480 mm)
1
4
/
/
Cuff Range:
Weight:
For arms 9” to 13” in circumference
1
/
Main Unit: approxꢀ 20 2 oz (580 g)including
batteries
2
/
Cuff: approxꢀ 4 5 oz (125 g)
Accessories:
Cuff, instruction manual,
Printing paper: 2 rolls
Optional parts: AC Adaptor
Specifications subject to change without noticeꢀ
11
This equipment generates and used radio frequency energy and if not installed and used properly,
that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio
and television receptionꢀ It has been type tested and found to comply with the limits for a Class
B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules,
which are designed to provide reasonable protection against such interference in a residential
installationꢀ However, there is no guarantee that interference will not occur in a particular
installationꢀ If this equipment does cause interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-
-
-
-
reorient the receiving antenna
relocate the computer with respect to the receiver
move the computer away from the receiver
plug the computer into a different outlet so that computer and receiver are on different
branch circuitsꢀ
If necessary, the user should consult the dealer or an experienced radio/television technician
for additional suggestionsꢀ The user may find the following booklet prepared by the Fedral
Communications Commision helpful:
“How to Identify and Resolve Radio-TV Interference Problems”ꢀ This booklet is available from
the US Government Printing Office, Washington, DꢀCꢀ, 20402, Stock Noꢀ 004-000-00345-4ꢀ
LICENSED UNDER Uꢀ Sꢀ PATꢀ
CUSTOMER SERVICE
4829419ꢀ4942516ꢀ4896260ꢀ4531132ꢀ4825364,4686622ꢀ4121284
TOLL FREE: 1-800-634-4350
4396976ꢀ4371923ꢀ4471385ꢀ4120583ꢀ4435732,4672457ꢀ4739396
12
Limited One Year Warranty
YOUR OMRON MODEL HEM-713C Digital Blood Pressure Monitor is warranted to be free from manufacturing
defects for a period of one year under normal useꢀ This warranty extends only to the original retail purchaserꢀ
Should repair be needed, within the warranty period, ship the unit and receipt as proof of purchase prepaid to
OMRON HEALTHCARE, INCꢀ, 300 Lakeview Parkway, Vernon Hills, Illinois 60061, together with $5ꢀ00 for return
shipping and insuranceꢀ
We will either repair or at our option replace free of charge any parts necessary to correct defects in material
or workmanshipꢀ The above warranty is complete ad exclusiveꢀ The warrantor expressly disclaims liability for
incidental, special or consequential damages of any natureꢀ (Some status do not allow the exclusion or limitation of
incidental or consequential damages so the above limitation or exclusion may not apply to youꢀ)
Any implied warranties arising by operation of law shall be limited in duration to the term of this warrantyꢀ (Some
states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to youꢀ)
This warranty gives you specific legal rights, and you may have other rights which vary from state to stateꢀ As
condition to operation of your warranty, the enclosed registration card must be completed and sent to us within 10
days from the date of purchaseꢀ
Caution
Changes or modifications not expressively approved by OMRON HEALTH CARE, INCꢀ could void the user’s
authority to operate this productꢀ
Note
Potential For RadiofTelevision Interference (for UꢀSꢀAꢀ only)
This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC rulesꢀ
These limits are designed to provide reasonable protection against harmful interference in a residential installationꢀ
The product generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communicationsꢀ Howeverꢀ there is no guarantee
that interierence will not occur in a particular installationꢀ If the product does cause harmful interference to radio or
television reception, which can be determined by turning the product off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antennaꢀ
Increase the separation between the product and receiverꢀ
Connect the product into an outlet on a circuit different from that to which the receiver is connectedꢀ
Consult the dealer or an experienced radiofTV technician for helpꢀ
Potential For RadiofTelevision Interference (for Canada only)
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as
set out in the interferencEH:ausing equipment standard entitled “Digital Apparatus”, ICES’{)03 of the Canadian
Department of Communicationsꢀ
Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de
Classe B prescrites dans la norme sur Ie materiel brouilleurꢀ “Appareils Numeriques”, NMBꢀ{J03 ildictee par Ie
ministre des communicationsꢀ
Distributed by
OMRON HEALTHCARE,INC.
300 Lakeview Parkway
Vernon Hills, Illinois 60061
0692581-7 A
OMRON uses recycled paper to help preserve our natural recourcesꢀ
13
|