Omron Healthcare Blood Pressure Monitor HEM 703CP User Manual

Instruction Manual  
Automatic Digital  
Blood Pressure Monitor  
Model HEM-703CP  
HEM-703CP-xxxx 0692581-7 A  
 
Name and Function of Each Part  
Main Unit  
Systolic Bood Pressure Display  
Diastolic Blood Pressure and Pulse Display  
Printing Paper  
Air Jack  
Paper Cutter  
MODE Selector Button  
SET Button  
SPHYG/CLOCK Button  
START Button  
PRINT / PAPER FEED Button  
Cuff  
Tab  
Air Plug  
Air Tube  
2
 
Preparations for Use  
1 How to insert the batteries  
1ꢀ Take off the battery cover at the back of  
the main unit by sliding it in the direction  
indicated by the arrow symbolꢀ  
Replacement  
• When the “Replace Batteries” symbol  
Battery Cover  
(
) flashes during measurement,  
please replace the batteries with the  
new onesꢀ  
• When the batteries have run down,  
random numbers may be displayedꢀ  
Points to be careful about whan using  
the batteries  
• When replacing the batteries please  
replace all four batteries at onceꢀ  
• Use the same kind of batteriesꢀ  
Take out weak batteries quickly so as to  
avoid causing damage to the machineꢀ  
• Remove the batteries when the unit is  
not used for extended periodsꢀ  
2ꢀ Install 4 “AA” size batteries attached so  
that the  
+
and  
-
polarities on the  
batteries correctly match the polarities in  
the battery compartmentꢀ  
3ꢀ Replace the coverꢀ  
3
 
Preparations for Use  
2 How to Set Time and Date  
3 Plug in and Turn on  
1ꢀ When batteries are installed, the display  
shows PM 12:00ꢀ  
1ꢀ Insert the air plug into the air jack on the  
left side of the main unit correctlyꢀ  
2ꢀ When the MODE button  
is pressed  
down, the “month” sign is displayedꢀ  
When the SET button is pressed down,  
the figure for the month increasesꢀ Adjust  
the “month”ꢀ  
2ꢀ When the SPHYG/CLOCK button is  
changedtothesphygmomanometermode,  
all the LCD symbols are momentarily  
displayedꢀ This happens because the unit  
is running a check on the display and this  
state lasts for approximately one secondꢀ  
3ꢀ When the MODE button  
is pressed  
down after the “month” has been adjusted,  
the “day” sign is displayedꢀ Adjust the  
“day” in the same way as the “month”ꢀ  
Initial Display  
3ꢀ Once the LCD symbols vanish, the air  
release indication symbol ( ) starts  
flashingꢀ Please wait until the ( ) symbol  
goes outꢀ  
4ꢀ In the same manner select the “hour” and  
“minꢀ” with the MODE button  
and set  
each value with the SET button ꢀ AM and  
PM signs are switched in accordance with  
the “hour” adjsutmentꢀ  
Air release  
indication symbol  
4ꢀ When the preparations necessary before  
measurement have been completed, the  
unit emits a series of beeps and finally the  
“Ready to Measure” symbol ( ) will be  
displayedꢀ  
5ꢀ Press the MODE button for the last time  
and return the screen to normal time (hour,  
minꢀ) displayꢀ  
“Ready to Measure”  
Display  
4
 
Preparations for Use  
4 How to Set the Printing Paper  
Please be sure not to print without inserting  
printing paper as it will shorten the life span  
of the printer headꢀ  
4ꢀ Insert the printing paper in the installation  
section, and then attach the cover back to  
the main unit in such a way that the edge  
of the paper protrudes from the coverꢀ  
1ꢀ Slide the plastic printer cover in the  
direction indicated by the arrow symbol  
and remove it from the main unitꢀ  
5ꢀ When the PRINT/PAPER FEED button  
is pressed while the results of the  
measurement are shown on the digital  
display, these results, together with the  
date and time of measurement are printed  
outꢀ  
2ꢀ Peel off the glued edge of the prontlng  
paper included with the unit, and cut it off  
to about 2 inches with a pair of scissors,  
and then shape and cut the edge for easy  
insertion to the printer as shown in the  
figureꢀ  
Reverse  
6ꢀ When purchasing printing paper, ask at the  
shop where you purchased the main unit  
for further supplyꢀ Other brands of paper  
may be used providing the dimensions are  
smaller than 38mm wide and 20mm in di-  
ameterꢀ However the printing quality may  
differ a littleꢀ  
Inserting Direction  
Front  
3ꢀ Press the PRINT/PAPER FEED button  
while inserting the edge of the printing  
paper to the paper feeding slitꢀ When the  
edge of the paper protrudes sufficiently,  
release the button and stop feedingꢀ  
5
 
Preparations for Use  
5 Changing the Printer Ink  
Though not originally equipped with an ink  
roller, the HEM-703CP digital blood pressure  
monitor contains enough printer ink to last  
about two years when used once a day at  
normal room temperatureꢀ  
3ꢀ Insert the supplement ink roller into the  
allotted space next to the printerꢀ  
Supplement ink roller  
When the ink on the print out becomes light  
and hard to read, purchase a replacement ink  
roller from your retailer and install as fol-lowsꢀ  
1ꢀ Remove the printer coverꢀ  
4ꢀ Replace the printer coverꢀ  
2ꢀ Removethe ink, which came with the  
unit when you bought it, from the allotted  
spaceꢀ  
NOTE: The supplement ink roller should  
last about two years, however, if you  
need to replace the supplement ink  
roller, simply grasp the top of the ink  
roller and turn itslightlycounterc1ock-  
wise before lifting the roller from the  
printerꢀ  
6
 
Preparations for Use  
6 Attach the Cuff  
This cuff has eliminated the need for  
a
3ꢀ Place your arm on a table or a support with  
the palm facing upward so that the cuff is  
placed at the same level as the heartꢀ  
microphone thereby lessening possible  
interference from vibrations and noiseꢀ Fitting  
also has been made much easier through the  
widening of the artery oscillation detection  
areaꢀ  
1ꢀ Place the cuff on the left arm so that the air  
tube lies across the center of the armꢀ  
Artery  
no space  
2ꢀ Wrap the cuff pulling in a diagonal angle  
securely so that the cuff tab is positioned  
about one inch above the elbow joint of the  
inner your left upper armꢀ (Over the brachi-  
al artery)ꢀ  
There should be no space between the  
cuff and your armꢀ  
NOTE: If you have any difficulties wrap-ping  
cuff by yourself, we recom-mend that  
you ask someone to wrap the cuff for  
youꢀ  
about 1 inch  
7
 
Preparations for Use  
7 Apply Pressure to the Cuff  
1ꢀ When you press the start button, the pump  
operates and pressure is appliedꢀ When  
the pressure reaches 170mmHg, the  
pump stops automaticallyꢀ  
Depress the START  
button continuously  
untill the cuff is inflated  
up to the targeted  
pressureꢀ  
After the cuff has  
been inflated,  
release the START  
buttonꢀ  
Pressure being applied  
2ꢀ When the appropriate pressure has been  
reached, the air is automatically released  
and the value on the display window  
starts to decreaseꢀ After a while when the  
artery oscillations are detected, the ( )  
symbol starts flashing and the unit emits  
a beep-ing sound simultaneouslyꢀ The  
value shown on the display will continue  
to fallꢀ  
Notes:  
*
If your systolic blood pressure is higher  
than 140mmHg, the pump starts again and  
the cuff will be inflated up to 210mmHgꢀ  
If your systolic blood pressure is higher  
than 180mmHg, sufficient inflation will  
not be applied to the cuff by automatic  
reinflationꢀ In this case, inflate up to  
30mmHg higher than your expected  
systolic blood pressure by pressing the  
start button continuouslyꢀ While press-ing  
the start button, the cuff can be in-flated  
continuously, and when the start button  
is released, the pump stops and the cuff  
is no longer inflatedꢀ When the pressure  
reaches 300mmHg, the cuff deflates  
rapidlyꢀ  
*
*
During measurement, do not shake  
the cuff or the air tubeꢀ  
Targetted Blood  
Pressure Reached  
Indicated Value Drops  
Measuring  
*
When you want to stop measurememt,  
press SPHYG/CLOCK buttonꢀ The pres-  
sure will stop and the air is deflated rapidlyꢀ  
8
 
Preparations for Use  
8 Blood Pressure and Pulse are displayed  
1ꢀ When the unit has continued to deflate  
to a point when the artery oscillations are  
no longer detected, the unit will display  
the systolic and diastolic blood pressure  
values, along with a long beep, and causes  
the deflation indication symbol ( ) to start  
flashingꢀ After this, blood pressure and the  
pulse readings are displayed alter-natelyꢀ  
*
When you wish to stop measuring during  
operation, press the SPHYGICLOCK  
buttonꢀ The pump will stop and all the cuff  
pressure will be released rapidlyꢀ  
*
When the PRINT button is pressed while  
the results of the measurement are shown  
on the digital display, the results will be  
printedꢀ  
3ꢀ Measurement of the blood pressure is  
now completeꢀ The results will remain  
displayed even after the cuff is taken  
offꢀ If you wish to carry out repeated  
measurements, repeat the operation from  
Step 6ꢀ  
Measurement  
Completed  
When the deflation symbol begins to flash,  
the residual pressure in the cuff is then  
rapidly releasedꢀ  
*
The arm gradually becomes congested  
when measurements are repeatedly  
takenꢀ If you wish to take consecutive  
measurements, take off the cuff and  
wait at least 3 to 5 minutes between  
measurementsꢀ  
2ꢀ Upon total cuff deflation,  
a
series of  
beeps are emitted and the ( ) symbol is  
displayedꢀ  
Alternate Display  
4ꢀ When measurement is completed press  
the SPHYG/CLOCK button to return to the  
time displayꢀ If you should forget to press  
this button, the display will return to time  
display mode automatically after about 5  
minutesꢀ  
Blood Pressure  
Reading Display  
(for approxꢀ  
seconds)  
3
Pulse Reading  
Display  
(for approxꢀ 1ꢀ5  
seconds)  
*P: Stands for PULSEꢀ  
9
 
When Error Indication Symbols Appear  
The following special error symbols will appear in the display if the unit is being used incorrectly:  
ERROR SYMBOL  
CAUSE  
CORRECTION  
1ꢀ Cuff underinflated  
1) Release air pressure in cuff  
2) Wait 10 minutes before taking  
another readingꢀ  
3) Repeat “Instructions for Use”  
steps except inflate cuff 30  
mmHg higher than previous  
inflation valueꢀ  
2ꢀ Movement during  
measurement  
Residual air pressure  
in cuffꢀ  
1) Release air pressure in cuff  
2) Wait 10 minutes before taking  
another readingꢀ  
Cuff overinflated (more  
than 300 mmHg)ꢀ  
No pulse or blood  
pressure reading due to:  
1) Motion  
2) Very weak artery  
oscillation  
3) Repeat “Instructions for Use”  
steps  
10  
 
Specifications  
Power Source:  
Battery (four type “AA” dry cell batteries) 6V 4W  
Oscillometric Method  
Measurement Method:  
Display:  
Liquid Crystal Digital Display  
Measurement Range:  
Pressure: 0 ~ 280mmHg  
Pulse: 40 ~ 200/minute  
Accuracy:  
Pressure: within ± 3 mmHg  
Pulse: within ± 5% reading  
Pressure Detection:  
Capacitive Pressure Sensor  
Inflation:  
Automatic Pressure Application by a Pump  
Automatic pressure release valve  
Deflation and Rapid Air Release:  
Automatic-shut-off System  
When the internal pressure in the unit continues  
at less than 20mmHg for about 5 ~ 8 minutes, the  
mode changes automatically to clockꢀ  
Printer:  
Serial static impact printer  
Operating/Temperature, Humidity:  
StorageiTemperature, Humidity:  
Dimensions (Approxꢀ):  
+500F to +104°F (+100C to +40 0C) 30-85% RH  
-4°F to 140°F (-20°C to + 600C) 10-95% RH  
2
1
3
/
/
/
Main Unit:  
8
4” (w) X 5 8” (d) x 2 5” (h) (215  
x 130x 66 mm)  
Cuff: 5 2 “(w) x 18 5”(1) (140x 480 mm)  
1
4
/
/
Cuff Range:  
Weight:  
For arms 9” to 13” in circumference  
1
/
Main Unit: approxꢀ 20 2 oz (580 g)including  
batteries  
2
/
Cuff: approxꢀ 4 5 oz (125 g)  
Accessories:  
Cuff, instruction manual,  
Printing paper: 2 rolls  
Optional parts: AC Adaptor  
Specifications subject to change without noticeꢀ  
11  
 
This equipment generates and used radio frequency energy and if not installed and used properly,  
that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio  
and television receptionꢀ It has been type tested and found to comply with the limits for a Class  
B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules,  
which are designed to provide reasonable protection against such interference in a residential  
installationꢀ However, there is no guarantee that interference will not occur in a particular  
installationꢀ If this equipment does cause interference to radio or television reception, which can  
be determined by turning the equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
-
-
-
-
reorient the receiving antenna  
relocate the computer with respect to the receiver  
move the computer away from the receiver  
plug the computer into a different outlet so that computer and receiver are on different  
branch circuitsꢀ  
If necessary, the user should consult the dealer or an experienced radio/television technician  
for additional suggestionsꢀ The user may find the following booklet prepared by the Fedral  
Communications Commision helpful:  
“How to Identify and Resolve Radio-TV Interference Problems”ꢀ This booklet is available from  
the US Government Printing Office, Washington, DꢀCꢀ, 20402, Stock Noꢀ 004-000-00345-4ꢀ  
LICENSED UNDER Uꢀ Sꢀ PATꢀ  
CUSTOMER SERVICE  
4829419ꢀ4942516ꢀ4896260ꢀ4531132ꢀ4825364,4686622ꢀ4121284  
TOLL FREE: 1-800-634-4350  
4396976ꢀ4371923ꢀ4471385ꢀ4120583ꢀ4435732,4672457ꢀ4739396  
12  
 
Limited One Year Warranty  
YOUR OMRON MODEL HEM-713C Digital Blood Pressure Monitor is warranted to be free from manufacturing  
defects for a period of one year under normal useꢀ This warranty extends only to the original retail purchaserꢀ  
Should repair be needed, within the warranty period, ship the unit and receipt as proof of purchase prepaid to  
OMRON HEALTHCARE, INCꢀ, 300 Lakeview Parkway, Vernon Hills, Illinois 60061, together with $5ꢀ00 for return  
shipping and insuranceꢀ  
We will either repair or at our option replace free of charge any parts necessary to correct defects in material  
or workmanshipꢀ The above warranty is complete ad exclusiveꢀ The warrantor expressly disclaims liability for  
incidental, special or consequential damages of any natureꢀ (Some status do not allow the exclusion or limitation of  
incidental or consequential damages so the above limitation or exclusion may not apply to youꢀ)  
Any implied warranties arising by operation of law shall be limited in duration to the term of this warrantyꢀ (Some  
states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to youꢀ)  
This warranty gives you specific legal rights, and you may have other rights which vary from state to stateꢀ As  
condition to operation of your warranty, the enclosed registration card must be completed and sent to us within 10  
days from the date of purchaseꢀ  
Caution  
Changes or modifications not expressively approved by OMRON HEALTH CARE, INCꢀ could void the user’s  
authority to operate this productꢀ  
Note  
Potential For RadiofTelevision Interference (for UꢀSꢀAꢀ only)  
This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15  
of the FCC rulesꢀ  
These limits are designed to provide reasonable protection against harmful interference in a residential installationꢀ  
The product generates, uses and can radiate radio frequency energy and, if not installed and used in accordance  
with the instructions, may cause harmful interference to radio communicationsꢀ Howeverꢀ there is no guarantee  
that interierence will not occur in a particular installationꢀ If the product does cause harmful interference to radio or  
television reception, which can be determined by turning the product off and on, the user is encouraged to try to  
correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antennaꢀ  
Increase the separation between the product and receiverꢀ  
Connect the product into an outlet on a circuit different from that to which the receiver is connectedꢀ  
Consult the dealer or an experienced radiofTV technician for helpꢀ  
Potential For RadiofTelevision Interference (for Canada only)  
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as  
set out in the interferencEH:ausing equipment standard entitled “Digital Apparatus”, ICES’{)03 of the Canadian  
Department of Communicationsꢀ  
Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de  
Classe B prescrites dans la norme sur Ie materiel brouilleurꢀ “Appareils Numeriques”, NMBꢀ{J03 ildictee par Ie  
ministre des communicationsꢀ  
Distributed by  
OMRON HEALTHCARE,INC.  
300 Lakeview Parkway  
Vernon Hills, Illinois 60061  
0692581-7 A  
OMRON uses recycled paper to help preserve our natural recourcesꢀ  
13  
 

Miele Dishwasher 05 585 951 User Manual
Nady Systems Speaker System PSS300 User Manual
National Instruments Computer Hardware PXI 8460 User Manual
NEC Printer 4600N User Manual
Nikon Binoculars 10x36DCF User Manual
NordicTrack Treadmill NTL159070 User Manual
North Star Portable Generator M165951C User Manual
Panasonic Car Video System CQRX65EU User Manual
Panasonic DVD Recorder WJ HD220 User Manual
Parasound Stereo Amplifier 275 V2 User Manual